22 Signal Connections
Figure 3-5: Connection to Open Collector Output
For more operation information on the encoder feedback signals,
refer to section 4.9.
3.3 Origin Signal ORG
The origin signals (ORG1-ORG4) are used as input signals for the
origin of the mechanism.
The input circuit of the ORG signals is shown below. Usually, a
limit switch is used to indicate the origin on one axis. The specifi-
cations of the limit switch should have contact capacity of +24V @
6mA minimum. An internal filter circuit is used to filter out any high
frequency spikes, which may cause errors in the operation.
Figure 3-6: Origin Signal ORG
When the motion controller is operated in the home return mode,
the ORG signal is used to inhibit the control output signals (OUT
Vue de la page 31