Adlink ACL-8112 Series Manuel d'utilisateur Page 77

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 94
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 76
C Language Library
69
7.10 _8112_AD_Set_Mode
Description
This function is used to set the A/D trigger and data transfer mode by
means of writing data to the mode control register. The hardware initial
state for the ACL-8112 is set as AD_MODE_1 software( internal) trigger
with program polling data mode.
A/D Mode Description
AD_MODE_0 External Trigger, Software Polling
AD_MODE_1 Software Trigger, Software Polling
AD_MODE_2 Timer Trigger, DMA Transfer
AD_MODE_3 External Trigger, DMA Transfer
AD_MODE_4 External Trigger, Interrupt Transfer
AD_MODE_5 Software Trigger, Interrupt Transfer
AD_MODE_6 Timer Trigger, Interrupt Transfer
AD_MODE_7 Not Used
Note:
All analog input modes selection should match with the hardware
settings, which is described in the hardware users manual.
Syntax
int _8112_AD_Set_Mode(int ad_mode )
int _8112pg_AD_Set_Mode(int ad_mode )
Argument:
ad_mode:
AD trigger and data transfer mode
( please refer above table.)
Return Code:
ERR_NoError
ERR_BoardNoInit
ERR_InvalidMode
Vue de la page 76