20
Installation
The internal voltage can be set to -5V or -10V which is selected by JP1 for
the ACL-8112DG/HG and JP8 for the ACL-8112PG. Possible configurations
are specified in Figure 2.9. Note that the internal reference voltage is used
only when JP2 of the ACL-8112DG/HG or JP6 and JP7 of the ACL-8112PG
is set to internal reference.
Reference Voltage is
-5V (default setting)
JP1 /
JP8
-10V
-5V
Reference Voltage is
-10V
JP1 /
JP8
-10V
-5V
Figure 2.9 Internal Reference Voltage Setting
2.12 A/D Input Range Setting
(This section is for the ACL-8112PG only)
The A/D input range of the ACL-8112PG can be set to ±5V or ±10V using
JP9.
A
/D Input Range is +/-
5V (default setting)
JP9
10
5
JP9
10
5
A
/D Input Range is +/-
10V