Adlink cPCIS-2500 Series Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Matériel Adlink cPCIS-2500 Series. ADLINK cPCIS-2500 Series User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - CompactPCI

cPCIS-2501 3U CompactPCI 6-slot Cubic Chassis User’s Guide

Page 2

This page intentionally left blank.

Page 3 - Revision Date Changes

Getting Started • 5 2 Getting Started In this chapter, we will describe the unpacking procedure for the cPCIS-2501 and installation procedures for Co

Page 4 - Getting Service from ADLINK

6 • Getting Started CompactPCI Card Installation/Removal Procedure 1. Place the chassis on a level surface. Remove the blanking plates where requir

Page 5 - Table of Contents

Getting Started • 7 To remove the module, press the locking button (if necessary), and reverse steps 1 through 5 above. System Card Fully Inserte

Page 6

8 • Getting Started CompactPCI PSU Installation/Removal Procedure The installation and removal procedures for a CompactPCI PSU are the same as those

Page 7 - Introduction

Getting Started • 9 2.3 Powering Up the System Set the main power switch in the lower right corner of the rear panel to the off position ( O ). Set

Page 8 - 1.3 Specifications

This page intentionally left blank.

Page 9 - 1.4 Mechanical Drawing

Backplane • 11 3 Backplane In this chapter, we will describe the backplanes for the cPCIS-2501, the cBP-3206 is a 3U CompactPCI 32-bit backplane and

Page 10

12 • Backplane Mechanical Drawing cBP-3206 RearViewcBP-3206 Front View1 - P21 - P16 - P26 - P1CN1 CN2 JP8 - JP10

Page 11 - Getting Started

Backplane • 13 Pin Assignment ¾ [1 – P1] System Slot Pin Z A B C D E F 25 GND +5V REQ64# ENUM# +3.3V +5V GND24 GND AD[1] +5V V(I/O)

Page 12 - Insert Module

This page intentionally left blank.

Page 13 - Locking Button

14 • Backplane ¾ [1 – P2] System Slot Pin Z A B C D E F 22 GND GA4 GA3 GA2 GA1 GA0 GND21 GND CLK6 GND NC NC NC GND20 GND CLK5 GND NC NC NC

Page 14 - Handle Engages

Backplane • 15 ¾ [2 – P1] – [6 – P1] Peripheral Slot Pin Z A B C D E F 25 GND +5V REQ64# ENUM# +3.3V +5V GND 24 GND AD[1] +5V V(I/O) A

Page 15 - 2.3 Powering Up the System

16 • Backplane ¾ CN1 / CN2 – ATX Power Connector Pin Signal Pin Signal 1 +3.3V 11 +3.3V 2 +3.3V 12 -12V 3 GND 13 GND 4 +5V 14 PS_ON_L 5 GND 15

Page 16

Backplane • 17 3.2 cBP-3061 Power Backplane The cBP-3061 is a PICMG 2.11 CompactPCI 3U 47-pin power backplane for one power module. It is used by the

Page 17 - Backplane

18 • Backplane Pin Assignment ¾ CN1 – Power Sense Connector Pin # Signal Name 1 V1_Sense 2 GND_S 3 V2_Sense 4 V3_Sense 5 NC ¾ CN2 – Power Sense

Page 18 - Mechanical Drawing

Backplane • 19 ¾ CN4 – Modular Power 47P Connector Pin Signal Pin Signal 47 ACL/-DC IN 31 GA2 46 ACN/+DC IN 30 V1 SENSE 45 CGND 29 V1ADJ 44

Page 19 - Pin Assignment

20 • Backplane ¾ CN7 –AC/DC in Let Connector Pin # Signal Name 1 ACN/DC+ 2 ACL/DC- 3 CGND ¾ CN8 – IPMB Connector Pin # Signal Name 1 IPMB_SCL

Page 20

Cooling System • 21 4 Cooling System The cPCIS-2501 is equipped with two bottom access removable fans for intake to provide an effectively cooled envi

Page 21

22 • Cooling System 2. Lift the grill and attached fan module out of the chassis. Remove the remaining two screws attaching the fan module to the g

Page 22

Cooling System • 23 4.2 Fan Removal and Replacement To remove the fan module from the chassis, follow the Air Filter Removal and Replacement Procedu

Page 23 - Specifications

©Copyright 2005, 2010 ADLINK Technology Inc. All Rights Reserved. Manual Rev. 1.01, November 10, 2010 Part Number: 50-15041-1010 The information

Page 24

This page intentionally left blank.

Page 25

Power Supply Unit • 25 5 Power Supply Unit The cPCIS-2501 is equipped with ADLINK’s cPS-H325/AC CompactPCI power module. 5.1 CompactPCI: cPS-H325/AC

Page 26

26 • Power Supply Unit Input Characteristics • Input Voltage: Typ. 90-264VAC • Power Factor Correction: Meets Harmonic Correction IEC1000-3-2. Power

Page 27 - Cooling System

Power Supply Unit • 27 Symbol: "★" OVP built-in; "@" Adjustable; "#" Remote sensing; "≡" 3rd-wire Load Sh

Page 28 - Cooling System

This page intentionally left blank.

Page 29

Important Safety Instructions • 29 Important Safety Instructions Read and follow all instructions marked on the product and in the documentation befor

Page 30

30 • Important Safety Instructions z Lithium Battery provided (real time clock battery) “CAUTION – Risk of explosion if battery is replaced by an inc

Page 31 - Power Supply Unit

Getting Service from ADLINK Customer Satisfaction is top priority for ADLINK TECHNOLOGY INC. If you need any help or service, please contact us. ADLIN

Page 32 - Output Characteristics

Table of Contents • v Table of Contents 1 Introduction ...1 1.1 Pro

Page 33

This page intentionally left blank.

Page 34

Introduction • 1 1 Introduction 1.1 Product Definition The cPCIS-2501 3U CompactPCI 6-slot Cubic Chassis is designed for 3U CompactPCI cards and modul

Page 35

2 • Introduction 1.2 Features • Compact size, 4U high enclosure for 3U CompactPCI cards w/o rear I/O • Board Space: 1 system slot, 5 peripheral slot

Page 36

Introduction • 3 1.4 Mechanical Drawing cPCIS-2501 Front ViewcPCIS-2501 Side View