26 Operation Theory
Trigger Modes
Post-Trigger Acquisition
Use post-trigger acquisition when you want to perform scans right
after a trigger signal. The number of scans to be performed after
the trigger signal is specified by the PSC_counter, as illustrated in
Figure 4-2. The total acquired data length is equal to:
(number_of_channels_enabled_for_scan_acquisition
) * PSC_counter