Adlink ACL-8112 Series Manuel d'utilisateur Page 83

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 92
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 82
C Language Library 75
7.16 _8112_AD_DMA_Stop
Description
This function is used to stop the DMA data transfer. After executing this
function, the internal A/D trigger is disabled and the A/D timer ( timer #1
and #2) is stopped. The function returns the number of data’s which
have been transferred, no matter if the A/D DMA data transfer is
stopped by this function or by the DMA terminal count ISR.
Syntax
int _8112_AD_DMA_Stop( int *count )
int _8112pg_AD_DMA_Stop( int *count )
Argument:
count:
the number of A/D converted data which
has beentransferred.
Return Code:
ERR_NoError
ERR_BoardNoInit
ERR_AD_DMANotSet
Example:
See demo program 'AD_Demo4.C'