Express-BASE6 Users ManualPage 30
JP1: AT/ATX MODE
In AT mode, JPY1 shorts PS_ON# to ground
directly to force power on. See 8.6 AT Power
Mode on p. 38.
Jumper Status
1-2 ATX Mode <<<<
2-3 AT Mode
1
2
3
CN2: PWR_OK Config
Jumper Status
1-2 Add 3.3V Pullup with 10K to signal PWR_OK
3-4 Connect PWRGOOD of ATX power supply <<<<
5-6 Connect PWRGOOD of onboard DCDC regulator
Note: <<<< indicates default setting
6.18 Power Jumper Settings
JP2: PS_ON# Signal Source
Jumper Status
1-2 SUS_S3# <<<<
2-3 SUS_S5#
1
2
3
All ADLINK modules support S3 mode and
consecutive power down of ATX power supply.
For modules that connect the S3 signal, PS_ON#
should always be set to SUS_S3# as source (even when S3 mode is disabled in the BIOS). For
modules that do not bring out the S3 signal, PS_ON# should be set to SUS_S5# as source.
JP3: AT Power 5V Setting
With an AT power supply is connected to
the Express-BASE6, JP3 can be used to
provide 5VSB to the COM module from
the carrier board.
Jumper Status
1-2 AT without P5V <<<<
2-3 AT with P5V
1
2
3
JP3: 5VSB to Module Source
Jumper Status
1-2 5VSB produced on
carrier from Vcc
2-3 5VSB from ATX power
supply
3-4 No 5VSB from module